RO System Troubleshooting - General


Problem Possible Causes Solution
Inlet pressure low Low supply pressure Correct incoming supply pressure
Cartridge filters plugged Replace filters
Solenoid valve malfunction Replace solenoid valve and/or coil
Permeate flow low Low water temperature Adjust water temperature
Low system pressure Adjust control valve
Membranes fouled Clean or Replace Membranes
Pump noisy Low inlet flow See "Inlet pressure low" above
Permeate quality poor Low Inlet flow Adjust control valve
Low system pressure See above
Recovery too high Reduce recovery
Membranes fouled Clean or Replace Membranes
Membranes damaged Replace Membranes
Feed pressure present even after tank full Solenoid malfunction Replace solenoid
Coil malfunction Replace coil
Controller malfunction Inspect or replace

 


Provisions Against Undue Operating Conditions


Troubleshooting High TDS

  1. Chlorine Damage
  2. Mechanical Damage to Permeate Tube
  3. Leaking O-Ring
  4. Telescoping Due to Excessive Pressure Drop
  5. Membrane Surface Abrasion
  6. Permeate Backpressure
  7. Hydraulic Shock

Troubleshooting Low Permeate Flow

  1. Colloidal Fouling
  2. Metal Oxide Fouling
  3. Scaling
  4. Biological Fouling
  5. Membrane Dry Out
  6. Aged Preservative

Troubleshooting Low Salt Passage

  1. Compaction
  2. Organic Fouling

 

 
Back Home Up Next

 Operating Do's & Don'ts System Recovery Membrane Foulant Identif. System Troubleshooting Res. RO Troubleshooting Operation Parameters Record Keeping Pre-Start-up Check System Shut-Down Flocon Antiscalant Selection

Applied Membranes Product Selection Links:
[Reverse Osmosis Membranes] [Reverse Osmosis Systems][Home RO Systems][Seawater Desalination Reverse Osmosis Systems] [Media Filters, Carbon Filters, Water Softeners, Etc.] [RO Filters & Housings] [RO Membrane Housings/Pressure Vessels] [Residential RO Components] [Commercial RO Components] [RO Pumps] [Membrane Chemicals] [Ultravioloet (UV) Systems] [Ozone][Water Quality Testers  (SDI)]

 

All Content on this site is  intended for informational purposes for experienced water treatment professionals only.  Applied Membranes, Inc. does not assume any liability for any damages caused by the misapplication or misinterpretation of any of the information contained on this website.
© Applied Membranes, Inc. 2007